When adding requirements on openings on the corresponding compartmentation wall, it’s easy to miss an opening.
It could be windows that are above-cut range, a new model where the architect has added openings, or to place multiple requirements on i.e. a façade.
----------------------------------------------------------------------------
Run the tool, and if there are any unrated openings on the wall the tool will place a requirement with the rating “unconnected”.
Select the requirement and change the rating from Unconnected to the correct value.
----------------------------------------------------------------------------
The same could be used to add multiple requirements on the northern facade
----------------------------------------------------------------------------
Select all window requirements and change values.