In the spring of 2022 release, the ellipse compartmentation family has been changed to a 7-point adaptive compartment.
Start by checking the length of the curved wall, and notice the height of the wall.
Note: If the architect used "Attach top/bottom" functionality, the Unconnected height will be incorrect.
Note: The Adaptive compartmentation will not appear with the legend tool, manually place the requirement of the ordinary compartmentation family if necessary.
----------------------------------------------------------------------------
The family requires 7 points to be placed, it's possible to trace the center of the wall for placing centrical. Place the first point on either a wall or a floor to get the compartmentation to have a height and not a depth.
----------------------------------------------------------------------------
Change the Fire_Top parameter to the wall height. Note that the adaptive compartmentation is not connected to the wall.
----------------------------------------------------------------------------
Use Connect family to manually connect the family to the wall. Fire_GUID is now not empty.
----------------------------------------------------------------------------
Repeat with all the curved walls which need to have fire requirements.